Medisana BU 514

Medisana BU 514 priručnik

(1)
  • GB
    WARNING
    Read the instruction manual carefully before
    using this device, especially the safety
    instructions, and keep the instruction manual
    for future use. Should you give this device to
    another person, it is vital that you also pass on
    these instructions for use.
    Safety Instructions
    The unit is intended only for use in the home. Consult your doctor prior to
    using the blood pressure monitor if you are concerned about health matters.
    Only use the unit for its intended purpose in accordance with the instructions
    for use. Warranty claims become void if the unit is misused. i
    Please consult your doctor prior to using the unit if you suffer from illnesses
    such as arterial occlusive disease. i
    The unit may not be used to check the heart rate of a pacemaker. i
    Pregnant women should take the necessary precautions and pay attention to
    their individual circumstances. Please consult your doctor if necessary. i
    Consult your physician to get more information about your blood pressure.
    A self-diagnosis and self-treatment based on the measured values may be
    dangerous. Always follow the instructions given by your physician! i
    If you experience discomfort during a measurement, such as pain in the upper
    arm or other complaints, press the START/STOP-button to release the air
    immediately from the cuff. Loosen the cuff and remove it from your arm. i
    The device only works correct with the fitting cuff. i
    The unit is not suitable for children. i
    Do not allow children to use the unit. Medical products are not toys! i
    Please ensure that the unit is kept away from the reach of children. i
    Do not put the air tube around your neck - danger of suffocation! i
    The swallowing of small parts like packaging bag, battery, battery cover and
    so on may cause suffocation. i
    The user needs to check that the equipment functions properly and that it is in
    proper working condition before being used. i
    Only the cuff provided can be used, and cannot be changed to any other
    branded cuff. It can only be replaced with a cuff of exactly the same type. i
    The device may not be operated in rooms with high levels of radiation or in
    the vicinity of high-radiation devices, such as radio transmitters, mobile tele-
    phones or microwaves, as this could cause functional defects or incorrect
    measurements. i
    Do not use the equipment where flammable gas (such as anaesthetic gas,
    oxygen or hydrogen) or flammable liquids (such as alcohol) are present. i
    No modification of this unit/device is allowed. i
    Please do not attempt to repair the unit yourself in the event of malfunctions,
    since this will void all warranty claims. Only have repairs carried out by
    authorised service centres. i
    Protect the unit against moisture. If liquid does manage to penetrate into the
    unit, remove the batteries immediately and do not continue to use the unit. In
    this case contact your specialist dealer or notify us directly. i
    Please do not use a dilution agent, alcohol or petrol to clean the unit. i
    Please do not hit the device heavily or let if fall down from a high place. i
    Do not use mobile phones in the range of the device. This may lead to mal-
    functions. i
    If the unit is not going to be used for a long period, please remove the
    batteries.
    SAFETY NOTES FOR BATTERIES
    Do not disassemble batteries! i
    Replace all batteries if the unit display shows the low battery symbol. i
    Never leave any low battery in the battery compartment since it may leak and
    cause damage to the unit. i
    Increased risk of leakage! Avoid contact with skin, eyes and mucous mem-
    branes! If battery acid comes in contact with any of these parts, rinse the
    affected area with copious amounts of fresh water and seek medical attention
    immediately! i
    If a battery has been swallowed, seek medical attention immediately! i
    Replace all of the batteries simultaneously! i
    Only replace with batteries of the same type, never use different types of
    batteries together or used batteries with new ones! i
    Insert the batteries correctly, observing the polarity! i
    Remove the batteries from the device if it is not going to be used for an exten-
    ded period of 3 months or more! i
    Keep batteries out of children's reach! i
    Do not attempt to recharge batteries! There is a danger of explosion! i
    Do not short circuit! There is a danger of explosion! i
    Do not throw into a fire! There is a danger of explosion! i
    Do not throw used batteries into the household refuse; put them in a
    hazardous waste container or take them to a battery collection point, at the
    shop where they were purchased!
    Blood pressure classification WHO
    These values have been specified by the World Health Organisation (WHO)
    without making any allowance for age.
    Low blood pressure systolic <100 diastolic <60
    Normal blood pressure (green display area )
    systolic 100 - 139 diastolic 60 - 89
    Forms of high blood pressure / hypertension
    Mild hypertension (yellow display area )
    systolic 140 – 159 diastolic 90 – 99
    Moderate hypertension (orange display area )
    systolic 160 – 179 diastolic 100 – 109
    Severe hypertension (red display area )
    systolic ≥ 180 diastolic ≥ 110
    Blood pressure that is too low represents just as great a health
    risk as blood pressure that is too high! Fits of dizziness may
    lead to dangerous situations arising (e.g. on stairs or in traffic)!
    Influencing and evaluating readings
    Measure your blood pressure several times, then record and compare the
    results. Do not draw any conclusions from a single reading. i
    Your blood pressure readings should always be evaluated by a doctor who is
    also familiar with your personal medical history. When using the unit regularly
    and recording the values for your doctor, you should visit the doctor from time
    to time to keep him updated. i
    When taking readings, remember that the daily values are influenced by se-
    veral factors. Smoking, consumption of alcohol, drugs and physical exertion
    influence the measured values in various ways. i
    Measure your blood pressure before meals. i
    Before taking readings, allow yourself at least 5-10 minutes rest. i
    If the systolic and diastolic readings seem unusual (too high or too low) on
    several occasions, despite correct use of the unit, please inform your doctor.
    This also applies to the rare occasions when an irregular or very weak pulse
    prevents you from taking readings.
    Starting up
    Insert / replace batteries
    You must insert the batteries provided before you can use your unit. The lid of
    the battery compartment is located on the underside of the unit. Open it by
    slightly pushing it and moving it upwards. Remove it and insert the 4 AA LR6
    type 1.5V batteries supplied. Ensure correct polarity when inserting the batteries
    (as marked inside the battery compartment). Close the battery compartment.
    Replace the batteries if the change battery symbol appears on the display or
    if nothing appears on the display after the unit has been switched on.
    6
    8
    r
    3. Month / date setting:
    The month figure starts to flash for setting. Keep pressing the MEM button
    until the actual month figure appears. Press SET button to confirm the
    month setting. Afterwards, the day needs to be set in the same way. After-
    wards, you can proceed with the time setting mode.
    3
    5
    4. Time setting:
    The hour figure starts to flash for setting. Keep pressing the MEM button i
    until the actual hour figure appears. Press SET button to confirm the
    hour setting and proceed in the same way for minute setting. Conclusively,
    CL appears in the display. You may delete stored values at this point -
    please check chapter Memory- clear of measurements“. Press SET button
    to leave the setting mode. If the batteries are changed, the set infor-
    mation is lost and needs to be input again.
    5
    Fitting the cuff
    1.
    2.
    3.
    4.
    5.
    Push the end piece of the air tube into the hole on the left side of the unit
    prior to use. i
    Slide the open end of the cuff through the metal bracket so that the Velcro
    fastener is on the outside and it becomes a cylindrical form (Fig.1). Slide the
    cuff over your left upper arm. i
    Position the air hose in the middle of your arm in line with your middle finger
    (Fig.2) (a). The lower edge of the cuff should be 2 - 3 cm above the crease of
    the elbow. (b). Pull the cuff tight and close the Velcro fastener (c). i
    Measure the pulse on your bare arm. i
    Only position the cuff on the right arm if it cannot be used on the left arm. Al-
    ways carry out measurements on the same arm. i
    Correct measuring position for sitting (Fig.3).
    Discontinuing a measurement
    If it is necessary to interrupt a blood pressure measurement for any reason
    (eg. the patient feels unwell) the START/STOP button can be pressed at
    any time. The device immediately decrease the cuff pressure automatically.
    4
    Display stored values
    Symbol Cause Correction
    Error messages and error remedying
    Error indicators
    The following symbol will appear on the display when measuring abnormal:
    E-1
    E-2
    E-3
    E-5
    Weak signal or
    sudden pressure
    change
    External strong
    disturbance
    Error during inflation
    process
    Abnormal blood
    pressure
    Weak batteries
    Put on the cuff correctly.
    Repeat the measurement in the
    correct way.
    When near cell phone or other high
    radiant device, the measurement may
    fail.
    During measurement, do not move and
    do not speak.
    Put on the cuff correctly. Make sure, that
    the hose is properly connected.
    Repeat the measurement.
    Repeat the measurement after relaxing
    30 minutes.
    If you get unusual readings for 3 times,
    please contact your doctor.
    The batteries are too low or empty.
    Replace all 4 batteries with new 1.5 V
    type AA LR6 batteries.
    The year figure starts to flash for setting. Keep pressing the MEM button i
    until the actual year figure appears. Press SET button to confirm the year
    setting. Afterwards, you can proceed with the month/date setting mode.
    5
    3
    7
    Disposal
    This product must not be disposed of together with domestic waste. All users
    are obliged to hand in all electrical or electronic devices, regardless of
    whether or not they contain toxic substances, at a municipal or commercial
    collection point so that they can be disposed of in an environmentally accep-
    table manner.
    Remove the batteries before disposing of the device/unit. Do not dispose of old
    batteries with your household waste, but at a battery collection station at a recyc-
    ling site or in a shop. Consult your local authority or your supplier for information
    about disposal.
    Explanation of symbols
    IMPORTANT
    Follow the instructions for use!
    Non-observance of these instructions
    can result in serious injury or damage
    to the device.
    WARNING
    These warning notes must be observed
    to prevent any injury to the user.
    CAUTION
    These notes must be observed to prevent
    any damage to the device.
    NOTE
    These notes give you useful additional
    information on the installation or
    operation.
    Device classification: type BF applied part
    LOT number
    Manufacturer
    Date of manufacture
    Common factors of wrong measurements
    Please keep quiet for 5-10 minutes and avoid eating,
    drinking alcohol, smoking, exercising and bathing
    before taking a measurement. All these factors will
    influence the measurement result.
    Remove any garment that fits closely to your
    upper arm.
    Always measure on the same arm (normally left).
    Measurements should be taken regularly at the
    same time of each day, as the blood pressure varies
    even during the day.
    Any effort to support the arm during measurement
    may increase the measured blood pressure.
    Make sure, you are in a comfortable, relaxed posi-
    tion and do not move or constrict your muscles
    during measurement. Use a cushion to support your
    arm if necessary.
    If the arm artery lies lower or higher than the heart,
    a false reading will be obtained.
    A loose or open cuff causes false readings.
    With repeated measurements , blood accumulates
    in the arm which can lead to false reading.
    Consecutive blood pressure measurements should
    be repeated after 1 minute pause or after the
    arm has been held up in order to allow the
    accumulated blood to flow away.
    4
    Scope of supply
    Please check first of all that the unit is complete.
    The following parts are included as standard:
    • 1 MEDISANA blood pressure monitor BU 514
    • 1 cuff with air tube
    • 4 batteries (type AA, LR6) 1.5 V
    • 1 storage pouch
    • 1 instruction manual
    Please contact your supplier if you notice any transport damage on unpacking
    the unit.
    What is blood pressure?
    Blood pressure is the pressure created in the blood vessels by each heart beat.
    When the heart contracts (= systole) and pumps blood into the arteries, it brings
    about a rise in pressure. The highest value is known as the systolic pressure
    and is the first value to be measured. When the cardiac muscle relaxes to take
    in fresh blood, the pressure in the arteries also falls. Once the arteries are re-
    laxed, a second reading is taken – the diastolic pressure.
    How is blood pressure measured?
    The MEDISANA BU 514 is a blood pressure unit which is used to measure
    blood pressure at the upper arm. The measurement is carried out by a micro-
    processor, which, via a pressure sensor, measures the vibrations resulting from
    the inflation and deflation of the cuff over the artery.
    Settings
    1. User setting:
    Press SET button when power off, or appear on the display. By
    pressing MEM-button you may choose between user , or .
    Press SET button to confirm the user setting. Afterwards, you can proceed with
    the year setting mode.
    5
    3
    5
    The readings are automatically saved in the previously selected memory
    ( or ). Up to 90 measured values with date and time can be stored
    in each memory.
    The measurement readings remain on the display. The unit switches off
    automatically after approx. 180 seconds if no buttons are pressed. The unit
    may also be switched off using the START/STOP button .
    WARNING
    Do not take any therapeutic measures on the basis of a self
    measurement. Never alter the dose of a medicine prescribed
    by a doctor.
    6.
    7.
    4
    Please contact the distributor resp. the service centre if you can’t solve the
    problem. Do not disassemble the unit by yourself.
    Problem Check Cause and solutions
    No power
    No inflation
    Err appears
    and the
    measurement
    is aborted
    Leak cuff
    Troubleshooting
    Check the battery power
    and if the polarity is
    correct.
    Check for proper hose
    condition and if it is
    properly connected to
    the device.
    Check whether you
    have moved the arm
    during inflation or if you
    have talked during
    measurement.
    Check whether the cuff
    is too loose or damaged.
    Replace all batteries and pay
    attention to correct polarity
    during insertion.
    Connect the air hose properly.
    Use a new cuff.
    Keep your arm and your body
    still.
    Do not talk during measure-
    ments.
    Put on the cuff correctly and
    close it tightly. Use a new cuff.
    Cleaning and care
    Remove the batteries before cleaning the unit. Clean the unit using a soft cloth
    lightly moistened with a mild soapy solution. Never use abrasive cleaning
    agents, alcohol, naphta, thinner or gasoline etc.. Never immerse the unit or any
    component in water. Be cautiious not to get any moisture in the main unit. i
    Do not wet the cuff or attempt to clean the cuff with water. Using a dry cloth,
    gently wipe away any excess moisture that may remain on the cuff. Lay the cuff
    flat in an unrolled position and allow the cuff to air dry. i
    Do not expose the unit to direct sunlight; protect it against dirt and moisture.
    Do not expose the unit to extreme hot or cold temperatures. Keep the device in
    the storage case when not in use. Store the unit in a clean and dry location.
    Guidelines / Standards
    This blood pressure monitor meets the requirements of the EU standard for non-
    invasive blood pressure monitors. It is certified in accordance with EC
    Guidelines and carries the CE symbol (conformity symbol) “CE 0297”.
    The blood pressure monitor corresponds to European standards EN 1060-3, EN
    81060-1 and EN 81060-2. The specifications of EU Guideline “93/42/EEC of the
    Council Directive dated 14 June 1993 concerning medical devices” are met. You
    can request the complete Conformity Declaration from Medisana GmbH,
    Jagenbergstrasse 19, 41468 Neuss, Germany, or you can also download it from
    the Medisana homepage (www.medisana.de).
    Electromagnetic compatibility: (see attached leaflet)
    Name and model
    Display system
    Memory slots
    Measuring method
    Power supply
    Blood pressure measuring range
    Pulse measuring range
    Maximum error tolerance for
    static pressure
    Maximum error tolerance for
    pulse rate
    Pressure generation
    Deflation
    Automatic switch-off
    Operating conditions
    Storage conditions
    Dimensions (L x W x H)
    Cuff
    Weight (main unit)
    Item number
    EAN number
    Acessories
    MEDISANA Blood pressure monitor BU 514
    Digital display
    2 x 90 measurement values
    Oscillometric
    6 V=, 4 x 1.5V batteries AA LR6
    0 – 299 mmHg
    40 – 199 beats/min.
    ± 3 mmHg
    ± 5 % of the value
    Automatic with pump
    Automatic
    After approx. 180 seconds
    +5 °C to +40 °C,
    15 to 85 % max. relative humidity
    -20 °C to +55 °C,
    10 to 85 % max. relative humidity
    Approx. 130 x 109 x 60 mm
    22 - 36 cm for adults
    Approx. 333 g without batteries
    51165
    40 15588 51165 3
    - Cuff M 22 - 36 cm for adults with
    average upper arm circumference
    Art. No. 51168 / EAN 40 15588 51168 4
    - Cuff, L 32 - 42 cm for adults with upper
    arm of large circumference
    Art. No. 51169 / EAN 40 15588 51169 1
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    :
    Technical specifications
    In accordance with our policy of continual product improvement, we
    reserve the right to make technical and visual changes without notice.
    The current version of this instruction manual can be found under
    www.medisana.com
    Please contact your supplier or the service centre in case of a claim under the
    warranty. If you have to return the unit, please enclose a copy of your receipt and
    state what the defect is.
    The following warranty terms apply:
    1. The warranty period for MEDISANA products is 3 years from date of purchase.
    In case of a warranty claim, the date of purchase has to be proven by means
    of the sales receipt or invoice.
    2. Defects in material or workmanship will be removed free of charge within the
    warranty period.
    3. Repairs under warranty do not extend the warranty period either for the unit
    or for the replacement parts.
    4. The following is excluded under the warranty:
    a. All damage which has arisen due to improper treatment, e.g.
    nonobservance of the user instructions.
    b. All damage which is due to repairs or tampering by the customer or
    unauthorised third parties.
    c. Damage which has arisen during transport from the manufacturer to the
    consumer or during transport to the service centre.
    d. Accessories which are subject to normal wear and tear as batteries, cuff etc..
    5. Liability for direct or indirect consequential losses caused by the unit are
    excluded even if the damage to the unit is accepted as a warranty claim.
    Warranty and repair terms
    For service, accessories and spare parts, please contact:
    MEDISANA GmbH, Jagenbergstr. 19, 41468 NEUSS,
    GERMANY.
    +44 20 38680977
    service.gb@medisana.com
    3
    5
    i
    i
    i
    i
    After the cuff has been appropriately positioned,the measurement can begin:
    Taking a blood pressure measurement
    1.
    2.
    3.
    4.
    Switch the unit on by pressing the START/STOP button . i
    If the START/STOP button is pressed, all display characters are shown
    (display test). This test can be used to check that the display is indicating
    properly and in full. i
    The unit is ready for measurement. The number 0 flashes for 2 seconds and
    two short beeps are emitted. The device then automatically inflates the cuff
    slowly in order to measure your blood pressure. The rising pressure in the
    cuff is shown on the display. i
    The unit inflates the cuff until sufficient pressure has built up for a measure-
    ment. Then the unit slowly releases air from the cuff and carries out the
    measurement. When the device detects the signal, the heart symbol on
    the display starts to flash, you can hear the beep for every heartbeat once
    the heartbeat signal is detected.
    4
    4
    DE/GB
    51165 09/2018 Ver.1.2
    Instruction Manual
    Please read carefully!
    1
    2
    2
    3
    4
    5
    6
    7
    8
    9
    q
    w
    e
    r
    t
    0
    z
    u
    i
    o
    Contraindications
    Proper use
    The device is intended for measuring the blood
    pressure from the upper arm of an adult.
    The device is not suitable for measuring the
    blood pressure of children. Ask your doctor
    before using it on older children.
    Persons who suffer from arrhythmia, diabetes,
    cardiovascular problems or who have had a stroke
    should consult their doctor before using the device.
    IP21
    Protection: IP21
    GB Unit and LCD-Display
    Blood Pressure Monitor BU 514 Cover for Battery Compartment
    MEM button (Memory Recall) START/STOP button SET button
    Battery Compartment (on underside) Push-in Connector for air tube
    LCD screen (display) Display of Date/Time Display of Systolic
    Pressure Display of Diastolic Pressure Pulse symbol Display of
    Pulse Rate Change Battery symbol Arrhythmia display (arrhythmia
    cordis) Memory Location number Memory-Symbol
    Blood Pressure Indicator (green - yellow - orange - red)
    User memory 1 / 2
    Unit and LCD display
    1
    2
    4
    6
    5
    7
    8
    9
    q
    0
    w
    e
    r
    z
    t
    u
    i
    o
    3
    2. Year setting:
    Blood Pressure Monitor BU 514
    This unit features 2 separate memories, each with a capacity of 90 memory
    slots. Results are automatically stored in the memory selected by the user.
    Press the MEM button when power off, to call up the measured values
    stored. Press the MEM button again All values average appear on the display.
    to call up the last measurement value. Repeatedly pressing the MEM button
    displays the respective values measured previously. If you have reached the final
    entry and do not press a button, the unit automatically switches itself off after
    approximately 8 seconds in memory recall mode. Memory recall mode can be
    exited at any time by pressing the START/STOP button , which will also switch
    the unit off. The oldest value is deleted if 90 measured values have been stored in
    the memory and a new value is saved.
    4
    3
    3
    3
Medisana BU 514

Trebate pomoć?

Broj pitanja: 0

Imate li pitanja u vezi s proizvodom BU 514 trgovačke marke Medisana ili vam treba pomoć? Ovdje postavite svoje pitanje. Navedite jasan i sveobuhvatan opis problema i vašeg pitanja. Što više pojedinosti navedete za svoje pitanje i pitanje, lakše je drugim vlasnicima proizvoda BU 514 trgovačke marke Medisana pravilno odgovoriti na vaše pitanje.

Ovdje besplatno pogledajte priručnik za proizvod trgovačke marke . Ovaj je priručnik pod kategorijom , a ocijenio ga je sljedeći broj osoba: prosječnom ocjenom od . Ovaj je priručnik dostupan na sljedećim jezicima: . Imate li pitanja u vezi s proizvodom trgovačke marke ili vam treba pomoć? Ovdje postavite svoje pitanje

Značajke proizvoda BU 514 trgovačke marke Medisana

Brend Medisana
Model BU 514
Proizvod Tlakomjer
EAN 4015588511653
Jezik Engleski, Nizozemac, Njemački, Francuski, Španjolski, Talijanski, Švedski, Portugalski, Polirati, Ruski, Finski, Rumunski, Turski, Grčki, Madžarski
Vrsta datoteke PDF
Značajke
Memorijski registri 90
Memorijska funkcija
Broj korisnika 2korisnik(ci)
Podržane opcije postavljanja Nadlaktica
Tip -
Boja proizvoda Green, White
Dijastolički krvni tlak
Sistolički krvni tlak
Mjerenje brzine pulsa
Prikaz sata/datuma
Funkcija govora -
Srednji arterijski tlak
Veličina manžete 22 - 36cm
Klasifikacija vrijednosti Svjetske zdravstvene organizacije (WHO)
Detekcija aritmije
Zaslon
Vrsta zaslona -

Povezani priručnici za proizvode

Tlakomjer Medisana