  • Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cpsww.com/registration.
    Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical
    support. Register your product now to receive the benefits of CyberPower ownership.
    (SAVE THESE INSTRUCTIONS)
    This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
    Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
    CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
    contaminants. (Please see specifications for acceptable temperature and humidity range).
    CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before
    servicing the batteries. There are no user serviceable parts inside except for the battery.
    CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
    CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
    grounded. If you need to de-energize this equipment, turn off and unplug the unit.
    CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
    CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment,
    ANSI/NFPA 75.
    CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
    accordance with the National Electric Code, ANSI/NFPA 70.
    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
    applications. DO NOT use in any circumstance that would affect operation and safety of life support equipment, any medical applications or
    patient care.
    DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
    from the aquarium can cause the unit to short out.
    DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation
    such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
    INTRODUCTION
    Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and
    performance during the lifetime of the product.
    UNPACKING
    Inspect the UPS upon receipt. The box should contain the following:
    (a) UPS unit (b) User’s manual (c) USB device cable
    *PowerPanel® Personal Edition software is available on our website. Please visit www.cpsww.com and go to the Software Section
    for a free download.
    HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
    1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity. If the rated capacities of the unit are
    exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
    2. There are many factors that can affect the amount of power that your electronic equipment will require. For optimal system performance
    keep the load below 80% of the unit’s rated capacity.
    HARDWARE INSTALLATION GUIDE
    1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to
    ensure the battery’s maximum charge capacity, it is recommended that you charge the battery
    for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is
    plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or
    turned off.
    2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals
    requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (eg.
    printer, scanner, speakers, etc.) into the full-time surge protection outlets. DO NOT plug a laser printer,
    paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical
    device into the “Battery and Surge Protected Outlets”. The power demands of these devices will
    overload and possibly damage the unit.
    3. To protect a fax, phone, or modem line, connect a telephone cable from the wall jack outlet to the IN jack
    of the UPS. Connect a telephone cable from one of the UPS OUT jacks to the modem port on the
    computer. The other UPS OUT jack can be used to protect a telephone or fax machine.
    4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
    protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
    conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips,
    and surge strips in conjunction with the UPS unit.
    5. Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will “beep” once.
    6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
    least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
    7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
    8. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every
    three months to ensure optimal battery life.
    9. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
    DESCRIPTION
    1. Battery and Surge Protected Outlets
    The unit has six battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power
    failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical
    device into the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage
    the unit.)
    2. Full-Time Surge Protection Outlets
    The unit has six surge suppression outlets.
    3. Power Switch
    Used as the master on/off switch for equipment connected to the battery power supplied outlets.
    To turn the UPS ON, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after a
    short beep.
    To turn the UPS OFF, press the power button for approximately 2 seconds - you will hear a constant tone (1 second) - and release after two
    short beeps.
    4. Power On Indicator
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
    5. Mute Button
    Press the button for 2 seconds to enable the audible alarm (beeps once) or disable (beeps twice) the audible alarm.
    6. Fault Indicator
    This LED is illuminated if there is a problem with the UPS.
    7. USB Port
    The USB port allows connection and communication between the USB port on the computer and the UPS unit.
    8. Communication Protection Ports
    Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11)
    9. Circuit Breaker
    Located on the side of the UPS, the circuit breaker provides overload and fault protection.
    10. Ground Screw
    The ground screw is used for any equipment that needs a chassis ground connection.
    11. Outlets Designed for AC Adapters
    The UPS unit has four widely-spaced outlets. AC power adapters can be plugged into the UPS without overlapping or blocking adjacent
    outlets.
    REPLACING THE BATTERY
    Replacement of batteries located in an OPERATOR ACCESS AREA.
    1. When replacing batteries, replace with the same number of the following battery: CyberPower / RB1270B for AVRG750U; CyberPower /
    RB1290A for AVRG900U.
    2. CAUTION! Risk of Energy Hazard, 12V, maximum 9 Ampere-hour battery. Before replacing batteries, remove conductive jewelry such as
    chains, wrist watches, and rings. High energy through conductive materials could cause severe burns.
    3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
    4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic.
    CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING
    TO LOCAL REGULATIONS.
    TO REPLACE THE BATTERY
    1. Turn off and unplug all connected equipment.
    2. Unplug it from the AC power source.
    3. Turn the UPS upside down.
    4. Remove the 1 retaining screw.
    5. Slide the battery compartment cover completely off of the unit.
    6. Remove the battery from the compartment.
    7. Disconnect the battery wires from the battery.
    8. Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery.
    9. Put the battery back into the compartment.
    10. Slide back the battery compartment cover and tighten the retaining screw.
    11. Charge the unit for 8 hours to fully charge the battery.
    REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead-acid batteries
    collects used batteries for recycling, as required by local regulations.
    Problem Possible Cause Solution
    Full-time surge protection outlets
    stop providing power to
    equipment. Circuit breaker
    button is projecting from the side
    of the unit.
    Circuit breaker has been tripped due
    to an overload.
    Turn the UPS off and unplug at least one piece of
    equipment. Wait 10 seconds, reset the circuit breaker by
    pressing the button, and then turn the UPS on.
    The UPS does not perform
    expected runtime.
    Battery not fully charged. Recharge the battery by leaving the UPS plugged in.
    Battery is worn out.
    Contact CyberPower Systems about replacement batteries
    at
    tech@cpsww.com.
    The UPS will not turn on.
    The on/off switch is designed to
    prevent damage from rapidly turning
    it off and on.
    Turn the UPS off. Wait 10 seconds and then turn the UPS
    on.
    The unit is not connected to an AC
    outlet.
    The unit must be connected to a 120V 60Hz outlet.
    The battery is worn out.
    Contact CyberPower Systems about replacement batteries
    at
    tech@cpsww.com.
    Mechanical problem. Contact CyberPower Systems at tech@cpsww.com.
    The frequency is outside of the
    operating range of 57-63Hz.
    Turn the UPS off. Make sure the frequency range is within
    57-63Hz. Or you can turn the UPS on in battery mode.
    PowerPanel
    ®
    Personal Edition is
    inactive (all icons are gray).
    The USB cable is not connected.
    Connect the USB cable to the UPS unit and an open USB
    port on the back of the computer.
    The USB cable is connected to a
    bad USB port.
    Check for a different USB port and plug the cable in.
    The unit is not providing battery
    power.
    Shutdown your computer and turn the UPS off. Wait 10
    seconds and turn the UPS back on. This should reset the
    unit.
    Additional troubleshooting information can be found at “Support” at
    www.CPSww.com
    DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS
    Power
    Fault
    Alarm
    CONDITION
    On Off
    Off Normal
    On* Off
    Beep twice
    every 30 seconds
    Utility Failure- The UPS is providing power to battery
    power-supplied outlets from its battery.
    AVRG750U / AVRG900U
    Users Manual
    K01-0000312-00
    BASIC OPERATION
    INSTALLING YOUR UPS SYSTEM
    TROUBLESHOOTING
    IMPORTANT SAFETY INSTRUCTIONS
    PRODUCT REGISTRATION

Trebate pomoć?

Broj pitanja: 0

Imate li pitanja u vezi s proizvodom AVRG750U trgovačke marke CyberPower ili vam treba pomoć? Ovdje postavite svoje pitanje. Navedite jasan i sveobuhvatan opis problema i vašeg pitanja. Što više pojedinosti navedete za svoje pitanje i pitanje, lakše je drugim vlasnicima proizvoda AVRG750U trgovačke marke CyberPower pravilno odgovoriti na vaše pitanje.

Ovdje besplatno pogledajte priručnik za proizvod AVRG750U trgovačke marke CyberPower. Ovaj je priručnik pod kategorijom , a ocijenio ga je sljedeći broj osoba: 1 prosječnom ocjenom od 6.3. Ovaj je priručnik dostupan na sljedećim jezicima: Engleski. Imate li pitanja u vezi s proizvodom AVRG750U trgovačke marke CyberPower ili vam treba pomoć?

Značajke proizvoda AVRG750U trgovačke marke CyberPower

Brend CyberPower
Model AVRG750U
Proizvod Besprekidno napajanje (UPS)
EAN 649532610716
Jezik Engleski
Vrsta datoteke PDF
Značajke
Kapacitet izlazne snage (VA) 750VA
Izlazna snaga 450W
Operativni ulazni napon (min) 90V
Operativni ulazni napon (maks) 148V
Operativni izlazni napon (min) -V
Operativni izlazni napon (maks) -V
Ulazna frekvencija 60Hz
Nivo udarnog napona 1030J
Filtriranje šuma EMI/RFI
Zaštita od prenapona
Funkcije zaštite Zaštita od preopterećenja
Automatska regulacija napona (AVR)
Priključci i sučelja
Broj AC izlaznih utičnica 12
Vrsta izlaznih AC utičnica NEMA 5–15R
Strujni utikač NEMA 5-15P
Modemski (RJ-11) priključci 3
Broj USB 2.0 priključaka 1
Dizajn
Duljina kabela 1.5m
Veličina Compact
Boja proizvoda Cr✗
Sigurnost UL1778 4th, cUL 107.3-05, FCC/DoC Class B
RoHS sukladnost
Energy Star certifikat
Baterija
Tehnologija baterije Zabrtvljena olovna kiselina (VRLA)
Broj podržanih baterija 1
Tipično vrijeme backupa pri polovičnom opterećenju 7.6min
Tipično vrijeme backupa pri maksimalnom opterećenju 2.5min
Radni uvjeti
Raspon radne temperature (T-T) 0 - 40°C
Dozvoljeni raspon temperatura za skladištenje (T-T) -15 - 45°C
Opseg relativne vlažnosti pri radu (H-H) 0 - 90%
Dozvoljena nadmorska visina 0 - 2000m
Neoperativna nadmorska visina 0 - 15000m
Težina i dimenzije
Širina 309.8mm
Dubina 88.8mm
Visina 177.7mm
Težina 5624g